Alkali Resistant Spiral-wound Membrane
HB Series could achieve the concentration of cellulose, hemicelluloses, paper fiber and other compound, which also could be used in the purification of alkali liquor. The membrane element could maintain high-flux and stable operation for more than 12 months in strong alkali conditions.
Table 1-1: Parameter of Alkali Resistant NF Membrane Element
Product Model |
Average Flow Rate GPD(m3/d)
|
Average Retention Rate |
HB-NF53-4040 |
4600(17.4) |
98.0% |
HB-NF54-4040 |
3600(13.6) |
98.0% |
HB-NF53-8040 |
19300(73.1) |
98.0% |
HB-NF54-8040 |
15100(57.2) |
98.0% |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition: solution of 2,000ppm MgSO4, 580psi of operating pressure, 25℃ of temperature, pH7 and 15% of recovery rate.
Table 1-2: Parameter of Alkali Resistant UF Membrane Element
Product Model |
MWCO (Dalton) |
Average Flow Rate, GPD (m3/d) |
HB-UF51-4040 |
20000 |
12700(48.1) |
HB-UF52-4040 |
20000 |
9500(36.0) |
HB-UF51-8040 |
20000 |
52900(200.0) |
HB-UF52-8040 |
20000 |
42400(160.5) |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition: general specification based on pure water, 15psi of operating pressure, 25℃ of temperature, and 10% of recovery rate. Fluctuation range of flow for a single membrane element is ±25%.
Table 2: Size and Weight
Product Model |
Size, inch (cm) |
Weight |
||
A |
B |
C |
(kg) |
|
HB-NF53-4040 |
40 |
0.75 |
3.9 |
6 |
101.6 |
1.9 |
9.9 |
||
HB-NF54-4040 |
40 |
0.75 |
3.9 |
6 |
101.6 |
1.9 |
9.9 |
||
HB-NF53-8040 |
40 |
1.125 |
7.9 |
16 |
101.6 |
2.86 |
20.1 |
||
HB-NF54-8040 |
40 |
1.125 |
7.9 |
16 |
101.6 |
2.86 |
20.1 |
||
HB-UF51-4040 |
40 |
0.75 |
3.9 |
6 |
101.6 |
1.9 |
9.9 |
||
HB-UF52-4040 |
40 |
0.75 |
3.9 |
6 |
101.6 |
1.9 |
9.9 |
||
HB-UF51-8040 |
40 |
1.125 |
7.9 |
16 |
101.6 |
2.86 |
20.1 |
||
HB-UF52-8040 |
40 |
1.125 |
7.9 |
16 |
101.6 |
2.86 |
20.1 |
Table 3: Operation and Cleaning Parameters
Product Model | HB-NF | HB-UF |
Max Operating Pressure | 580psi | 145psi |
Pressure Drop of Single Membrane | <8psi | <8psi |
Recovery | 15% | 15% |
Max Operating Temperature | 60℃ | 80℃ |
Max Cleaning Temperature | 60℃ | 80℃ |
PH Range of Continuous Working | 3.0-14.0 | 2.0-10.0 |
PH Range of Cleaning | 2.0-14.0 | 1.5-11.5 |
Allowable Maximum Contents of Residual Chlorine | 500ppm-hours | 500ppm-hours |
Inlet Water | NTU<1 | NTU<1 |
SDI<5 | SDI<5 |
Storage Condition
1. Before the first use, all membrane elements must be stored under the original packaging conditions.
2. Store in a cool, dry and the place that is not directly exposed to sunlight or artificial lighting. Storage temperature stays at 0℃ to 30℃, and the longest storage time is 6 months.