Acid Resistant Spiral-wound Membrane
Products of HA Series could achieve the concentration of metals from acid solution that contains sulfuric acid of less than 20% and phosphoric acid of less than 30%, as well as the purification of acid liquor. The membrane element could maintain high-flux and stable operation for more than 12 months in strong acid conditions.
Table 1-1: Parameter of Acid Resistant NF Membrane Element
Product Model |
Average Flow Rate GPD(m3/d)
|
Average Retention Rate |
HA-NF33-4040 |
4300(16.3) |
98.0% |
HA-NF34-4040 |
3400(12.9) |
98.0% |
HA-NF43-4040 |
4800(18.2) |
96.0% |
HA-NF44-4040 |
3800(14.4) |
96.0% |
HA-NF33-8040 |
18200(68.9) |
98.0% |
HA-NF34-8040 |
14200(53.7) |
98.0% |
HA-NF43-8040 |
20400(77.2) |
96.0% |
HA-NF44-8040 |
16000(60.6) |
96.0% |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition: solution of 2,000ppm MgSO4, 580psi of operating pressure, 25℃ of temperature, pH7 and 15% of recovery rate.
Table 1-2: Parameter of Acid Resistant and High Pressure UF Membrane Element
Product Model |
MWCO (Dalton) |
Average Flow Rate, GPD (m3/d) |
HA-UF33-4040 |
2500 |
4300(16.5) |
HA-UF34-4040 |
2500 |
3550(13.4) |
HA-UF33-8040 |
2500 |
18250(69.1) |
HA-UF34-8040 |
2500 |
14250(53.9) |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition: general specification based on pure water, 580psi of operating pressure, 25℃ of temperature, and 10% of recovery rate.
Table 1-3: Parameter of Acid Resistant and Low Pressure UF Membrane Element
Product Model |
MWCO (Dalton) |
Average Flow Rate, GPD (m3/d) |
HA-UF43-4040 |
10000 |
1850(7.0) |
HA-UF44-4040 |
10000 |
1400(5.3) |
HA-UF43-8040 |
10000 |
7700(29.1) |
HA-UF44-8040 |
10000 |
6050(22.9) |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition: general specification based on pure water, 30psi of operating pressure, 25℃ of temperature, and 10% of recovery rate.
Table 2: Size and Weight
Product Model | Size, inch (cm) | Weight | ||
A | B | C | (kg) | |
HA-NF33-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-NF34-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-NF43-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-NF44-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-NF33-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-NF34-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-NF43-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-UF33-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-UF34-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-UF33-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-UF34-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-UF33-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-UF44-4040 | 40 | 0.75 | 3.9 | 6 |
101.6 | 1.9 | 9.9 | ||
HA-UF43-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-UF44-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 | ||
HA-NF44-8040 | 40 | 1.125 | 7.9 | 16 |
101.6 | 2.86 | 20.1 |
Table 3: Operation and Cleaning Parameters
Product Model | HA-NF3 | HA-NF4 | HA-UF3 | HA-UF4 |
Max Operating Pressure | 1000psi | 580psi | 580psi | 145psi |
Pressure Drop of Single Membrane | <8psi | <8psi | <8psi | <8psi |
Recovery | 15% | 15% | 15% | 15% |
Max Operating Temperature | 80℃ | 50℃ | 50℃ | 50℃ |
Max Cleaning Temperature | 80℃ | 50℃ | 50℃ | 50℃ |
PH Range of Continuous Working | 0-12 | 0-12 | 0-12 | 0-12 |
PH Range of Cleaning | 0-13 | 0-13 | 0-13 | 0-13 |
Allowable Maximum Contents of Residual Chlorine | 500ppm-hours | 500ppm-hours | 500ppm-hours | 500ppm-hours |
Inlet Water | NTU<1 | NTU<1 | NTU<1 | NTU<1 |
SDI<5 | SDI<5 | SDI<5 | SDI<5 |
Storage Condition
1. Before the first use, all membrane elements must be stored under the original packaging conditions.
2. Store in a cool, dry and the place that is not directly exposed to sunlight or artificial lighting. Storage temperature stays at 0℃ to 30℃, and the longest storage time is 6 months.