Organic Solvent Spiral-wound Membrane
Products of HS Series are suitable for the coexistence of organic solvent and water, and it adopts hydrophilic membrane material. Extraction, recovery of the solvent and reduce the difficulty of wastewater treatment and energy consumption could be conducted, and in the following solvents, it can be normally operated for 12 months.
Methanol, alcohol, isopropyl alcohol, ethylene glycol, acetonitrile, acetone, ethyl acetate, dichloromethane, n-hexane, THF, NMP, DMF, DMA, DMSO and toluene.
Table 1-1 Parameter of Organic NF Membrane Element
Product Model |
Average Flow Rate GPD(m3/d)
|
Average Retention Rate |
HS-NF13-4040 |
4300(16.3) |
98% |
HS-NF14-4040 |
3300(12.5) |
98% |
HS-NF23-4040 |
4800(18.2) |
96% |
HS-NF24-4040 |
3700(14.0) |
96% |
HS-NF13-8040 |
18200(68.9) |
98% |
HS-NF14-8040 |
14200(53.7) |
98% |
HS-NF23-8040 |
20400(77.2) |
96% |
HS-NF24-8040 |
15900(60.2) |
96% |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition : MgSO4 solution of 2,000 ppm, 580psi of operating pressure, 25℃ of temperature, pH7and 15% of recovery rate.
Table 1-2: Parameter of Organic UF Membrane Element
Product Model |
MWCO (Dalton) |
Average Flow Rate, GPD (m3/d) |
HS-UF13-4040 |
2500 |
5100(19.3) |
HS-UF14-4040 |
2500 |
4000(15.1) |
HS-UF13-8040 |
2500 |
18250(69.1) |
HS-UF14-8040 |
2500 |
14250(53.9) |
· After operating for 24 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition : general specification based on pure water, 30psi of operating pressure, 25℃ of temperature, and 10% of recovery rate.
Table 1-3: Parameter of Organic UF Membrane Element
Product Model |
MWCO (Dalton) |
Average Flow Rate, GPD(m3/d) |
HS-UF23-4040 |
10000 |
1850(7.0) |
HS-UF24-4040 |
10000 |
1400(5.3) |
HS-UF23-8040 |
10000 |
7700(29.1) |
HS-UF24-8040 |
10000 |
6050(22.9) |
· After operating for 4 hours, measure the average rate of desalination. Fluctuation range of flow for a single membrane element is +25%/-25%.
· Measure Condition : general specification based on pure water, 30psi of operating pressure, 25℃ of temperature, and 10% of recovery rate.
Table 2: Size and Weight
Product Model |
Size,inch(cm) |
Weight |
||||||
A |
B |
C |
(kg) |
|||||
HS-NF13-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-NF14-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-NF23-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-NF24-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-NF13-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-NF14-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-NF23-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-UF13-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-UF14-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-UF13-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-UF14-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-UF23-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-UF24-4040 |
40 |
0.75 |
3.9 |
6 |
||||
101.6 |
1.9 |
9.9 |
||||||
HS-UF23-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-UF24-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
||||||
HS-NF24-8040 |
40 |
1.125 |
7.9 |
16 |
||||
101.6 |
2.86 |
20.1 |
Table 3: Operation and Cleaning Parameters
Product Model | HS-NF1 | HS-NF2 | HS-UF1 | HS-UF2 |
Max Operating Pressure | 1000psi | 580psi | 580psi | 145psi |
Pressure Drop of Single Membrane | <8psi | <8psi | <8psi | <8psi |
Recovery | 15% | 15% | 15% | 15% |
Max Operating Temperature | 60℃ | 50℃ | 50℃ | 50℃ |
Max Cleaning Temperature | 60℃ | 60℃ | 60℃ | 60℃ |
PH Range of Continuous Working | 2.0-12.0 | 2.0-12.0 | 2.0-12.0 | 2.0-12.0 |
PH Range of Cleaning | 1.0-12.0 | 1.0-12.0 | 1.0-12.0 | 1.0-12.0 |
Allowable Maximum Contents of Residual Chlorine | 500ppm-hours | 500ppm-hours | 500ppm-hours | 500ppm-hours |
Inlet Water | NTU<1 | NTU<1 | NTU<1 | NTU<1 |
SDI<5 | SDI<5 | SDI<5 | SDI<5 |
Storage Condition
1. Before the first use, all membrane elements must be stored under the original packaging conditions.
2. Store in a cool, dry and the place that is not directly exposed to sunlight or artificial lighting. Storage temperature stays at 0℃ to 30℃, and the longest storage time is 6 months.